Abstract Number: 2539

The Reliability Of a Novel Automated System For ANA Immunofluorescence Analysis In Daily Clinical Practice

Mohammed Alsuwaidi1, Margit Dollinger1, Martin Fleck1,2 and Boris P. Ehrenstein1, 1Rheumatology & Clinical Immunology, Asklepios Clinic Bad Abbach, Bad Abbach, Germany, 2Internal Medicine I, University Medical Center of Regensburg, Regensburg, Germany

Meeting: 2013 ACR/ARHP Annual Meeting

Keywords: ANA, autoantibodies, connective tissue diseases and laboratory tests, Lupus

  • Tweet
  • Email
  • Print
Session Information

Title: Systemic Lupus Erythematosus-Clinical Aspects III: Biomarkers, Quality of Life and Disease Indicators, Late Complications

Session Type: Abstract Submissions (ACR)

Background/Purpose:  Recently, automated interpretation (AI) systems for anti-nuclear antibody (ANA) analysis have been introduced based on assessment of indirect immunofluorescence (IIF) patterns. However, the reliability of these systems has not been assessed in routine clinical practice. Therefore, the diagnostic performance of a novel automated IIF reading system was compared with visual interpretation (VI) of IIF in daily clinical practice.

Methods:  ANA-IIF tests of consecutive serum samples from patients with suspected connective tissue disease were carried out using HEp-2 cells according to routine clinical care. VI was performed first by two laboratory experts independently; discrepant results were resolved by collegial discussion with a third expert. Afterwards, AI of IIF findings were obtained using a visual analyzer (Zenit G-sight, Menarini, Germany) utilizing novel automated pattern recognition algorithms. VI and AI readings were stratified as negative (serum dilution of 1:80 with no fluorescence), ambiguous (dilution of 1:80 with slight fluorescence, but no defined pattern) and positive (dilution of ≥ 1:80 with definite IIF pattern). Agreement rates between ANA results by AI and VI were calculated.  IIF patterns were categorized as either being homogeneous, fine granular, coarse granular, nucleolar, centromeric, or mitochondrial by AI and VI, respectively.

Results:  Of the 340 samples investigated, VI yielded 205 (60%) negative, 42 (12%) ambiguous and 93 (27%) positive results, whereas 82 (24%) were determined negative, 176 (52%) ambiguous and 82 (24%) positive by AI. Of the 82 negative samples by AI, 78 (95%) were also negative, 3 (4%) were ambiguous and 1 (1%) was positive as judged by VI. Of the 176 ambiguous samples by AI, 125 (71%) were negative, 30  (17%) also ambiguous and 21 (12%) positive by VI. Of the 82 positive samples by AI, 2 (2%) were negative, 9 (11%) ambiguous and 71 (87%) also positive by VI. AI displayed a diagnostic accuracy of 179/340 samples (53%) with a kappa-coefficient of 0.35 compared to VI as the gold standard. Solely relying on AI with VI only performed for all ambiguous samples by AI would have missed 1 of 93 (1%) positive results by VI, and misclassified 2 of 205 (1%) negative results by VI as positive. Of the 93 positive samples by VI, AI identified 36 (39%) IIF patterns correctly (18 (95%) of 19 homogeneous, 1 (3%) of 3 fine granular, 13 (65%) of 20 coarse granular, 2 (18%) of 11 nucleolar, 1 (33%) of 3 centromeric, and 1 (100%) of 1 mitochondrial patterns).

Conclusion:  Utilizing novel algorithms, AI of ANA-IIF displayed reliable detection of positive and negative results as confirmed by VI. However, there were a substantial number of ambiguous results as well as inconsistencies in the identification of the correct pattern by AI requiring additional VI analysis. In contrast to previous studies utilizing well defined biobank samples, the use of AI in daily clinical practice resulted only in a moderate reduction of the VI workload (82 of 340 samples: 24%), which was predominantly due to a large proportion of ambiguous AI-results.


Disclosure:

M. Alsuwaidi,
None;

M. Dollinger,
None;

M. Fleck,
None;

B. P. Ehrenstein,
None.

  • Tweet
  • Email
  • Print

« Back to 2013 ACR/ARHP Annual Meeting

ACR Meeting Abstracts - https://acrabstracts.org/abstract/the-reliability-of-a-novel-automated-system-for-ana-immunofluorescence-analysis-in-daily-clinical-practice/

Advanced Search

Your Favorites

You can save and print a list of your favorite abstracts during your browser session by clicking the “Favorite” button at the bottom of any abstract. View your favorites »

All abstracts accepted to ACR Convergence are under media embargo once the ACR has notified presenters of their abstract’s acceptance. They may be presented at other meetings or published as manuscripts after this time but should not be discussed in non-scholarly venues or outlets. The following embargo policies are strictly enforced by the ACR.

Accepted abstracts are made available to the public online in advance of the meeting and are published in a special online supplement of our scientific journal, Arthritis & Rheumatology. Information contained in those abstracts may not be released until the abstracts appear online. In an exception to the media embargo, academic institutions, private organizations, and companies with products whose value may be influenced by information contained in an abstract may issue a press release to coincide with the availability of an ACR abstract on the ACR website. However, the ACR continues to require that information that goes beyond that contained in the abstract (e.g., discussion of the abstract done as part of editorial news coverage) is under media embargo until 10:00 AM ET on November 14, 2024. Journalists with access to embargoed information cannot release articles or editorial news coverage before this time. Editorial news coverage is considered original articles/videos developed by employed journalists to report facts, commentary, and subject matter expert quotes in a narrative form using a variety of sources (e.g., research, announcements, press releases, events, etc.).

Violation of this policy may result in the abstract being withdrawn from the meeting and other measures deemed appropriate. Authors are responsible for notifying colleagues, institutions, communications firms, and all other stakeholders related to the development or promotion of the abstract about this policy. If you have questions about the ACR abstract embargo policy, please contact ACR abstracts staff at [email protected].

Wiley

  • Online Journal
  • Privacy Policy
  • Permissions Policies
  • Cookie Preferences

© Copyright 2025 American College of Rheumatology