Abstract Number: 158 • 2016 ACR/ARHP Annual Meeting
Musculoskeletal Ultrasound Is a Sensitive Imaging Tool for the Assessment of Dynamic Changes of Bone Erosions in Inflammatory Arthritis: A Comparative Analysis with High-Resolution Peripheral Quantitatve Computed Tomography
Background/Purpose: Correct detection of bone erosions is crucial both for diagnosis and for monitoring of treatment response in patients with inflammatory joint diseases. Musculoskeletal ultrasound…Abstract Number: 326 • 2016 ACR/ARHP Annual Meeting
Cortical Bone Changes in Pre- and Postmenopausal Healthy Women Measured with HR-pQCT
Background/Purpose: Increased fracture rates are well-recognized in adults with trabecular and cortical bone deficits, but cortical evaluation has been poorly studied. The aim of this…Abstract Number: 339 • 2016 ACR/ARHP Annual Meeting
Assessment of High-Resolution Peripheral Quantitative Computed Tomography Parameters and Markers of Bone Metabolism in Community-Dwelling Elderly with and without Vertebral Fractures – the Sao Paulo Ageing & Health Study
Background/Purpose: Bone mineral density(BMD) by dual X-ray absorptiometry(DXA) is currently standard clinical tool for predicting osteoporotic fracture. However, DXA doesn’t allow studying abnormalities that predict different…Abstract Number: 358 • 2015 ACR/ARHP Annual Meeting
Bone Microstructure Assessed By Hrpqct in Subjects with Hyperuricemia without Arthritis
Background/Purpose: Gouty arthritis is a common inflammatory joint disorder and hyperuricemia (HU) is known to be the main risk factor. Beside clinical signs of inflammation…Abstract Number: 1315 • 2015 ACR/ARHP Annual Meeting
Detecting Subtle Changes in Bone Structure Following Three-Month Anti-TNF Theraphy Using High-Resolution Peripheral Quantitative Computed Tomography
Background/Purpose: Radiographs have been traditionally used to detect bone erosions and joint space narrowing (JSN) in rheumatoid arthritis (RA), but they are not sensitive to…Abstract Number: 1323 • 2015 ACR/ARHP Annual Meeting
Reaching Consensus – Volumetric Joint Space Width Calculations in Finger Joints of Arthritis Patients
Background/Purpose: Joint space width (JSW) is suggested as an indirect measure of arthritis disease activity and could be used as a measure of radiographic progression…Abstract Number: 2047 • 2015 ACR/ARHP Annual Meeting
A Randomised Double-Blind Placebo-Controlled Trial of Vitamin D Supplementation in Juvenile-Onset Systemic Lupus Erythematosus: Effects on Microarchitecture Measured By HR-pQCT
Background/Purpose: Vitamin D has an important effect in bone quality and vitamin D deficiency in Juvenile-onset Systemic Lupus Erythematosus patients (JoSLE) may be associated with…Abstract Number: 2800 • 2015 ACR/ARHP Annual Meeting
Bone Microarchitecture and Bone Strength in Patients with Primary Sjögren’s Syndrome: A Case-Control Study Using HR-pQCT
Background/Purpose: To evaluate bone mineral density (BMD), microarchitecture, strength and prevalence of vertebral fractures (VF) in primary Sjögren's syndrome (pSS).Methods: We evaluated 71 female pSS…Abstract Number: 2553 • 2014 ACR/ARHP Annual Meeting
Compromised Volumetric Bone Density, Bone Microarchitecture and Bone Strength in Patients with Ankylosing Spondylitis: High-Resolution Peripheral Quantitative Computerized Tomography (HRpQCT) Based Study
Background/Purpose Patients with ankylosing spondylitis (AS) have high fracture risk. BMD, bone microarchitecture and strength determine fracture risk. However, in AS, DXA-based BMD measurements of…Abstract Number: 2136 • 2014 ACR/ARHP Annual Meeting
Rheumatoid Arthritis Erosion Detection and Measurement in Longitudinal Datasets Using High-Resolution Peripheral Quantitative Computed Tomography
Background/Purpose An operational case definition for identification of erosions imaged by HR-pQCT was achieved and tested in a first reliability exercise (RELEX-1) using cross-sectional data.…Abstract Number: 2143 • 2014 ACR/ARHP Annual Meeting
Cortical Breaks and Bone Erosions in the Hand Joints: A Cadaver Study Comparing Conventional Radiography with High-Resolution and Micro-Computed Tomography
Background/Purpose . Conventional radiography (CR) is considered the gold standard for diagnosing bone erosions in rheumatic diseases. However, High-Resolution peripheral Quantitative Computed Tomography (HR-pQCT) and…Abstract Number: 1192 • 2014 ACR/ARHP Annual Meeting
Erosions Detected By Magnet Resonance Imaging in Patients with Juvenile Idiopathic Arthritis (JIA) Are True Erosions As Visualized By Computed Tomography
Background/Purpose Chronic arthritis occurs relatively frequent in childhood. Patients with polyarticular disease might have a destructive disease course and thus a worse outcome. In adult…