Abstract Number: 1132

Compensated Polarized Microscopy for Crystal Identification Shows High Reliability Among Multiple Observers

José Antonio Bernal1, Mariano Andrés2,3, Salvador López-Salguero4, Vega Jovaní5, Paloma Vela3,6 and Eliseo Pascual7, 1Reumatología, Hospital Universitario del Vinalopó, Elche, Spain, 2Reumatología, Hospital General Universitario Alicante, Alicante, Spain, 3Universidad Miguel Hernández, Elche, Spain, 4Sección de Reumatología, Hospital General Universitario de Alicante, Alicante, Spain, 5Reumatología, Hospital general universitario de Alicante, Alicante, Spain, 6Reumatología, Hospital General Universitario de Alicante. Alicante. Spain, Alicante, Spain, 7Emeritus Professor, Universidad Miguel Hernández, Elche, Spain

Meeting: 2017 ACR/ARHP Annual Meeting

Date of first publication: September 18, 2017

Keywords: Calcium pyrophosphate dihydrate (CPPD), Crystal-induced arthritis, Gout and pseudogout

  • Tweet
  • Email
  • Print
Session Information

Date: Monday, November 6, 2017

Session Title: Metabolic and Crystal Arthropathies Poster I

Session Type: ACR Poster Session B

Session Time: 9:00AM-11:00AM

Background/Purpose:

The gold standard for crystal-related arthritis diagnosis remains synovial fluid analysis by a microscope fitted with compensated polarized filters as it has been shown an immediate, valid, easy to learn, and reliable procedure (for the last, only in two studies not designed for this purpose). The objective was to analyze the agreement between multiple observers in crystal identification using a compensated polarized optic microscope. Finding good reliability results between multiple observers would reinforce the value of the technique.

Methods:

Cross-sectional, observational study performed at a single center with consecutive synovial fluid sampling. Samples were immediately analyzed when possible or kept refrigerated at 4ºC. Five different observers analyzed samples under a compensated polarized optical microscope to detect and identify crystals, independently and blinded to clinical data. All observations were performed at 400x fields. It was recorded the presence and type of crystal (No crystals; monosodium urate -MSU-; and calcium pyrophosphate dihydrate -CPPD-). Inter-rater agreement by Cohen’s kappa (k) statistic was measure. Also, sub-analyses were performed on a) time of sample visualization (£24 hours or >24 hours of sampling) and b) expertise on crystal identification (£10 years or > 10 years).

Results:

Synovial fluid samples were obtained mostly from knees (67.3%), ankles (13.2%) and wrist (6.8%) of patients seen at rheumatology clinic or during admissions. Main rheumatic diseases were gout (33.8%), rheumatoid arthritis (18.4%), CPPD related arthritis (15%) and arthritis under study (8.3%). A total of 31 samples were analyzed by all five observers (155 observations). Overall k was 0.76 (CI95% 0.63-0.89) thus indicating good agreement. Agreement for detection was k 0.75 (CI95% 0.61-0,90) and k for MSU was 0.91 (CI95% 0.76-1.05) while for CPPD was 0.66 (CI95% 0.47-0.84). Regarding secondary endpoints, no differences were noted neither between observations made before or after 24 hours (p 0.68 for k comparison), nor in expertise in crystal analysis (p 0.63 for k comparison).

Conclusion:

Even requiring agreement among multiple observers, compensated polarized microscopy remains consistent in the detection and identification of crystals in synovial fluid, confirming its high utility in clinical practice.


Disclosure: J. A. Bernal, None; M. Andrés, None; S. López-Salguero, None; V. Jovaní, None; P. Vela, None; E. Pascual, AstraZeneca, 5,Grunenthal, 5.

To cite this abstract in AMA style:

Bernal JA, Andrés M, López-Salguero S, Jovaní V, Vela P, Pascual E. Compensated Polarized Microscopy for Crystal Identification Shows High Reliability Among Multiple Observers [abstract]. Arthritis Rheumatol. 2017; 69 (suppl 10). https://acrabstracts.org/abstract/compensated-polarized-microscopy-for-crystal-identification-shows-high-reliability-among-multiple-observers/. Accessed May 26, 2022.
  • Tweet
  • Email
  • Print

« Back to 2017 ACR/ARHP Annual Meeting

ACR Meeting Abstracts - https://acrabstracts.org/abstract/compensated-polarized-microscopy-for-crystal-identification-shows-high-reliability-among-multiple-observers/

Advanced Search

Your Favorites

You can save and print a list of your favorite abstracts during your browser session by clicking the “Favorite” button at the bottom of any abstract. View your favorites »

ACR Pediatric Rheumatology Symposium 2020

© COPYRIGHT 2022 AMERICAN COLLEGE OF RHEUMATOLOGY

Wiley

  • Home
  • Meetings Archive
  • Advanced Search
  • Meeting Resource Center
  • Online Journal
  • Privacy Policy
  • Permissions Policies
loading Cancel
Post was not sent - check your email addresses!
Email check failed, please try again
Sorry, your blog cannot share posts by email.